chapa perfilada
Revestimento de fachadas, de Coberturas
Click on the options to see the product range.
PUR
ROOFS
FAÇADES
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ISOTEC 27 |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofs
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ISOTECCOPPO |
ROOFS |
Incl. ≥ 10% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
(1) TOLERANCES: According to the European standard EN 14509. (2) Sandwich composite (insulated) panels for flat or pitched roofs
This roof insulated sandwich panel has a cover width of 1 000 mm. Made of a polyurethane (PIR) and two prepainted steel facings.
The upper plate has an identical modeling to the traditional Lusa tile.
The COPPOTEC panel is a thermally suitable solution for roofs/roofs where the traditional appearance is a requirement.
Indicated for sloping roofs with a minimum slope of 10%.
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
COPPOTEC |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofs
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ROOFTEC 3 |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of a polyurethane (PIR) and two prepainted steel facings, its outer facing is trapezoidal
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ROOFTEC 4 |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of rock wool (MW) and two prepainted steel facings, its outer facing is trapezoidal
MW
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ROOFTEC 4 FIRECLASS SOUND |
ROOFS |
Incl. ≥ 6% (2) ![]() |
2000 ≤ L ≤ 15000 |
A2s1d0 | 0.038 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of rock wool (MW) and two prepainted steel facings, its outer facing is trapezoidal
MW
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ROOFTEC 4 FIRECLASS SOUND |
ROOFS |
Incl. ≥ 6% (2) ![]() |
2000 ≤ L ≤ 15000 |
A2s1d0 | 0.038 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of a polyurethane (PIR) and two prepainted steel facings, its outer facing is trapezoidal
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ROOFTEC 5 |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of a polyurethane (PIR) and two prepainted steel facings, its outer facing is trapezoidal
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
AGROTEC 3 |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of a polyurethane (PIR) and two prepainted steel facings, its outer facing is trapezoidal
PUR
ROOFS
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
AGROTEC 5 |
ROOFS |
Incl. ≥ 6% (2) ![]() |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of a polyurethane (PIR) and two prepainted steel facings, its outer facing is trapezoidal
L
PD
N
PUR
FAÇADES
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
WALLTEC N600 WALLTEC N1000 |
FAÇADES |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 | |
AGROTEC N600 AGROTEC N1000 |
FAÇADES |
3000 ≤ L ≤ 15000 |
PUR = Cs3d0 | PIR = Bs2d0 | 0.020 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis roof insulated sandwich panel has a cover width of 1 000 mm. Made of a mineral wool core (MW) and two prepainted steel facings.
MW
FAÇADES
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
WALLTEC FIRECLASS |
FAÇADES |
2000 ≤ L ≤ 15000 |
A2s1d0 | 0.038 | |
WALLTEC FIRECLASS SOUND |
FAÇADES |
2000 ≤ L ≤ 15000 |
A2s1d0 | 0.038 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis ONDUTEC FIRECLASS insulated sandwich panel has a cover width of 1 000 mm. Made of rock wool (MW) and two prepainted steel facings, its outer facing is sinuzoidal
MW
ROOFS
FAÇADES
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ONDUTEC FIRECLASS SOUND |
ROOFS |
Incl. ≥ 6% (2) ![]() |
2000 ≤ L ≤ 15000 |
A2s1d0 | 0.038 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofsThis ONDUTEC FIRECLASS SOUND insulated sandwich panel has a cover width of 1 000 mm. Made of rock wool (MW) and two prepainted steel facings, its outer facing is sinuzoidal
MW
ROOFS
FAÇADES
Click + info
LENGTH - L (1) |
REACTION |
THERMAL |
|||
ONDUTEC FIRECLASS SOUND |
ROOFS |
Incl. ≥ 6% (2) ![]() |
2000 ≤ L ≤ 15000 |
A2s1d0 | 0.038 |
Note: despite panels being indicated for roofing, there are no contraindications to its use on facades.
(1) TOLERANCES: According to the European standard EN 14509.
(2) Sandwich composite (insulated) panels for flat or pitched roofs